- SMT labelling machines
- Multi-station labelling machines
- High precision labelling machines
- PCB labelling machines
- Pallet labelling machines
- Automatic labelling machines
- High-speed labelling machines
- Double-sided labeling machine
- Self-adhesive labeling machine
- FPC adhesive backing machine
- Mobile phone adhesive backing machine
- speaker sticker backing machine
- Automatic backing machine
- Automatic adhesive backing machine
- Search
Hyde energy CPA series pure water film
- Product:Hyde energy CPA series pure water film
- Catalogue:Adhesive backing machine
- Views:177710times
- Update:2013/3/26 15:39:57
- Call:133-6065-4218
CPA Series:
CPA series of low pressure reverse osmosis membrane elements include two 8 in. membrane (CPA2, CPA3-LD) and a 4 inches membrane (CPA2-4040). For those who need high volume and high rejection rate of groundwater treatment system, CPA series is your best choice.
Technical parameters:
Model |
CPA3-LD |
CPA2-4040 |
||
Type |
Size |
8 inch |
4 inch |
|
Membrane Polymer |
Composite Polyamide |
|||
Membrane Active Area |
ft² |
400 |
85 |
|
m² |
37.2 |
7.9 |
||
Performance |
Salt Rejection,% |
average |
99.7 |
99.5 |
Min. |
99.6 |
99.2 |
||
Permeate Flow |
gpd |
11000 |
2250 |
|
m3/d |
41.6 |
8.5 |
||
Test Condition |
NaCl, mg/l |
1500 |
||
Pressure,psi(MPa) |
225(1.55) |
|||
Temperature, ℃ |
25 |
|||
Permeate Recovery,% |
15 |
|||
pH Range |
6.5-7.0 |
|||
Application Data |
Maximum Applied Pressure,psi(MPa) |
600(4.14) |
||
Maximum Feed Flow,gpm (m3/h) |
75(17.0) |
16(3.6) |
||
Maximum Operating Temperature, ℃ |
45 |
|||
Feedwater pH Range |
2-10.8 |
2-10 |
||
Cleaning pH Range |
1-12.5 |
1-12 |
||
Maximum Feedwater Turbidity,NTU |
1.0 |
|||
Maximum Feedwater SDI 15 |
<5 |
|||
Maximum Chlorine Concentration, mg/l |
<0.1 |
|||
Minimum Ratio of Concentrate to |
5:1 |
|||
Maximum Pressure Drop for Each Elemen psi(MPa) |
10(0.07) |