SWC5 MAX desalination film

 SWC5 MAX desalination film

  • Product: SWC5 MAX desalination film
  • Catalogue:Adhesive backing machine
  • Views:177410times
  • Update:2019/8/15 17:52:53
  • Call:133-6065-4218

SWC5 is a seawater desalination film with high desalination rate and high water yield. It is suitable for systems requiring both energy conservation and water quality, and has obvious cost advantages in large seawater desalination plants. SWC5 diaphragm can be rolled into two 8-inch membrane elements, LD and MAX; It can also be made into 16-inch membrane element.

When using traditional pretreatment, LD technology ® can reduce colloid pollution, slow down the rise of pressure difference, and prolong the cleaning cycle.

The membrane area of the MAX membrane element is 440 ft2 (40.9 m2), which can save about 10% membrane quantity when using the same water flux design.

I. SWC5 MAX performance parameters of Hyde energy seawater desalination membrane

model

SWC5 MAX

specifications

8 inches

performance

Desalination rate

nominal

98%

The minimum

97%

Water rate

9900gpd (37.5m3/d)

type

Film material

Aromatic polyamide composites

structure

Roll type

Effective membrane area

440ft²(40.9㎡)

Test condition

solution

32000mg/L NaCl

pressure

800psi(5.5Pa)

The temperature

77°F(25℃)

The recovery rate of

10%

pH

6.5-7.0

* the performance parameters are obtained after the system runs steadily for 30 minutes. The actual test conditions may not be exactly the same as the above data, in which case the performance parameters are standardized data based on standard conditions. The deviation of water yield is within ±15 %

Ii. Use and restriction of products

Maximum operating pressure

600 psig (4.14MPa)

The largest water residual chlorine concentration

<0.1 mg/L

Maximum inlet temperature

113 °F (45 °C)

Operating pH range

2-11

Maximum inlet turbidity

1.0 NTU

The largest water SDI15

5.0

Maximum inflow

75gpm (17mm³/h)

Maximum pressure drop for single membrane elements

10psi (0.07MPa)


This is only a general constraint. For specific projects, more conservative operating parameters can ensure better performance and longer service life. For details, please refer to the relevant technical data of Hyde energy.

Iii. Product description

Disclaimer: the information and data provided herein are in good faith and in lieu of any warranty. All warranties, express or implied, including warranties of merchantability and fitness for a particular purpose, are hereby denied and excluded. The conditions and methods of use of our products are beyond our control. Hyde energy shall not be liable for the results or damages resulting from the use of this information and data. It is the responsibility of the user to determine the suitability of heidner's products for their particular use.