ESPA Series:

Energy-efficient ultra-low pressure RO Membrane ESPA® 。Currently,ESPA®Series 8-inch membrane, there are five models: ESPA1 (standard ultra-low pressure reverse osmosis membrane), ESPA2 (high rejection rate of ultra-low pressure reverse osmosis membrane), ESPA4 (ultra-high volume low pressure reverse osmosis membrane), ESPA2 MAX (high membrane area of the high rate of ultra-low pressure reverse osmosis membrane desalination) and ESPAB (high boron removal reverse osmosis membrane ultra-low voltage), 4-inch membrane has developed into three types: ESPA1-4040, ESPA2-4040 and ESPA4-4040.

ESPA Seres 8" Performance parameters

Model

ESPA1

ESPA2

ESPA2MAX

ESPAB

ESPA4

Type

Size

8 inch

Membrane Polymer

Composite Polyamide

Membrane Active Area

ft2

400

400

440

400

400

37.2

37.2

40.9

37.2

37.2

Performance

Salt Rejection,%

average

99.3

99.6

99.6

99.2

99.2

Min

99

99.5

99.5

99

99

Boron Rejection,%

93

93

96

Permeate Flow

gpd

12000

9000

12000

8600

12000

m3/d

45.4

34.1

45.4

32.6

45.4

Test Condition

NaClmg/L

1500

500

Pressure,psi(MPa)

150(1.05)

1000.7

Temperature,℃

25

Permeate Recovery,%

15

pH Range

6.5-7.0

Application Data

Maximum Applied Pressure

psi(MPa)

600(4.14)

Maximum Feed Flow,gpm(m3/h)

75(17.0)

Maximum Operating Temperature,℃

45

Feedwater pH Range

2-10

2-10.6

2-10.6

2-11

2-10

Cleaning pH Range

1-12

1-12

1-12

1-12.5

1-12

Maximum Feedwater Turbidity
NTU

1

Maximum Feedwater SDI 15

<5

Maximum Chlorine Concentration
mg/L

<0.1

Minimum Ratio of Concentrate to
Permeate Flow for any Element

5:1

Maximum Pressure Drop for Each Element
psi(MPa)

100.07

ESPASeres 4" Performance parameters

Model

ESPA1

ESPA2

ESPA4

Type

Size

4 inch

Membrane Polymer

Composite Polyamide

Membrane Active Area

ft2

85

85

85

7.9

7.9

7.9

Performance

Salt Rejection%

average

99.3

99.6

99.2

Min

99

99.4

99

Permeate Flow

gpd

2600

1900

2500

m3/d

9.8

7.2

9.5

Test Condition

NaClmg/L

1500

500

Pressurepsi(MPa)

150(1.05)

1000.7

Temperature,℃

25

Permeate Recovery%

15

pH Range

6.5-7.0

使

Maximum Applied Pressurepsi(MPa)

600(4.14)

Maximum Feed Flowgpm(m3/h)

16(3.6)

Maximum Operating Temperature,℃

45

Feedwater pH Range

2-10

2-10.6

2-10

Cleaning pH Range

1-12

1-12

1-12

Maximum Feedwater TurbidityNTU

1

Maximum Feedwater SDI15

<5

Maximum Chlorine Concentrationmg/L

<0.1

Minimum Ratio of Concentrate to
Permeate Flow for any Element

5:1

Maximum Pressure Drop for Each Element
psi(MPa)

100.07

Disclaimer: the information and data provided herein are in good faith and in lieu of any warranty. All warranties, express or implied, including warranties of merchantability and fitness for a particular purpose, are hereby denied and excluded. The conditions and methods of use of our products are beyond our control. Hyde energy shall not be liable for the results or damages resulting from the use of this information and data. It is the responsibility of the user to determine the suitability of heidner's products for their particular use.