ESNA membrane is a product developed by Hyde energy company with new technology, which has excellent energy saving effect. This series of nanofiltration membrane is mainly used to soften, remove pesticides and bacteria. Under standard test conditions, the desalination rate range of ESNA series is about 91-99%(see technical sheet for specific test conditions of each model).

ESNA film can also remove iron and TOC, allowing the penetration of monovalent salts such as Na and Cl, thus making it suitable for municipal drinking water system applications. Using advanced membrane technology and unique characteristics of headenergy, ESNA membrane can help the system significantly reduce operating costs and energy consumption.

Esna1-lf-ld is a high desalination nanofiltration membrane, which is used to soften and remove pesticides, bacteria and viruses. Low operating pressure, good energy saving effect, reduce installation and operation cost.

Esna1-lf-ld membrane element adopts patented 34 mil water inlet screen to prevent colloid fouling and improve membrane cleaning effect.

Esna1-lf-ld can be cleaned less frequently, reduce maintenance cost, and maintain stable performance.

The hardness removal rate of ESNA1-LF-LD is high. Esna1-lf-ld is available in 4 "and 8" specifications.


1. Performance parameters of esna1-lf-ld Hyde nanofiltration membrane, USA:

model

ESNA1-LF-LD

specifications

8 inches

performance

Desalination rate

nominal

93%

The minimum

88-97%

Water rate

9500gpd (36m3/d)

type

Film material

Aromatic polyamide composites

structure

Roll type

Feed water screen thickness

34mil(0.86mm)

Effective membrane area

400ft²(37.2㎡)

Test condition

solution

500mg/L NaCl

pressure

75psi(0.52Pa)

The temperature

77°F(25℃)

The recovery rate of

15%

pH

6.5-7.0


* for a typical 500mg/L underground water source, the operating temperature is 25℃ and the water flux is 22LMH, it is estimated that the calcium ion removal rate is 96%.

* the performance parameters are obtained after the system runs steadily for 10 minutes. The actual test conditions may not be exactly the same as the above data, in which case the performance parameters are standardized data based on standard conditions. The deviation range of water yield is within -20-+25%%% %.


Ii. Use and restriction of products:

Maximum operating pressure

600 psig (4.14MPa)

The largest water residual chlorine concentration

<0.1 mg/L

Maximum inlet temperature

113 °F (45 °C)

Operating pH range

1-12(25℃,30 分钟)

Maximum inlet turbidity

1.0 NTU

The largest water SDI15

5.0

Maximum inflow

85gpm (19.3mm³/h)

The high salinity water flux of the lowest

12gpm ( 2.7m3/h)

Maximum pressure drop for single membrane elements

10psi (0.07MPa)

This is only a general constraint. For specific projects, more conservative operating parameters can ensure better performance and longer service life. For details, please refer to the relevant technical data of Hyde energy.

Iii. Product description:

Disclaimer: the information and data provided herein are in good faith and in lieu of any warranty. All warranties, express or implied, including warranties of merchantability and fitness for a particular purpose, are hereby denied and excluded. The conditions and methods of use of our products are beyond our control. Hyde energy shall not be liable for the results or damages resulting from the use of this information and data. It is the responsibility of the user to determine the suitability of heidner's products for their particular use.